Home > News > Installing the Online Residual Chlorine Automatic Monitor for Swimming Pools in the Wrong Location = A Waste of Money! 4 Golden Installation Points Every Business Should Know
Related News
  • Three methods of COD water quality detector
  • Overview and Performance of Online Turbidity D...
  • Usage of Online COD Detector
  • Characteristics and Applications of Online COD...
  • What is COD standard solution
  • How to detect COD content in water quality
  • Why Buy Chinese Free Chlorine Sensors?
  • Lower Price, Higher Quality: Why Choose Chines...
  • Which industries are China's free chlorine se...
  • Why Recommend Chinese Online Residual Chlorine...
  • Installing the Online Residual Chlorine Automatic Monitor for Swimming Pools in the Wrong Location = A Waste of Money! 4 Golden Installation Points Every Business Should Know

    Time:August 1, 2025

      For businesses operating swimming pools, water quality safety is of utmost importance, and the residual chlorine content is one of the key indicators for measuring the water quality of swimming pools. After purchasing an online residual chlorine detector, businesses often focus on a core question: How should the Digital residual chlorine sensor be installed to ensure accurate measurement and convenient maintenance? If it is installed in the wrong location, it can lead to big troubles. It may cause the monitoring data to be inaccurate, which in turn affects the disinfection effect of the swimming pool and ultimately harms the health of consumers. Statistics show that there are quite a few swimming pool businesses that have been complained about due to sub - standard water quality caused by improper installation of online residual chlorine water quality analyzers.

    32c1c717034f21d19b5d08a0656ede3e_1754014653794327.jpeg

       Analyzing the Best Installation Locations for Swimming Pools and the Reasons

      1.  Main Circulation Pipeline Outlet 

      The main circulation pipeline outlet is a key node in the swimming pool's water circulation. The water flow here is stable, and it can represent the overall water quality of the pool. Installing the online residual chlorine detector at this location is like setting up a "core monitoring point" for the pool water quality. By monitoring the residual chlorine content at this location in real - time, businesses can comprehensively understand the overall situation of the pool water quality and adjust the disinfection strategy in a timely manner.

      2.  Independent Area of the Children's Pool 

    521f6f2bd411bba381741624a753591a_1754014667526635.png

      Children's bodies are more sensitive, and they are much more sensitive to residual chlorine than adults. Therefore, it is very necessary to install a detector separately in the independent area of the children's pool. This can precisely control the low - concentration range of residual chlorine in the children's pool, generally maintaining it at 0.3 - 0.5mg/L. It ensures that children can enjoy clean and hygienic water quality while swimming without being over - stimulated by residual chlorine.

      3. Pool Corners/Dead Water Areas 

      The corners and dead water areas of the pool are often overlooked. The water flow in these locations is poor, bacteria are likely to grow, and the residual chlorine content is often low. Installing an automatic residual chlorine sensor in these places is like equipping the "hygiene dead corners" of the pool with a pair of eyes, which can detect local water quality hazards in a timely manner and avoid health problems caused by bacterial growth.

      4. Downstream of the Chemical Mixing Area 

    d20d919fdaa1b860dc7900b700cdf0ef_1754014581629836.jpg

      After adding disinfectants to the swimming pool, it is necessary to ensure that the chemicals are fully diffused before monitoring. If the detector is installed directly in the chemical mixing area, uneven chemical addition may cause fluctuations in the readings, affecting the accuracy of the monitoring results. Therefore, installing the detector downstream of the chemical mixing area is a very wise choice.

        Practical Suggestions for Businesses

    85242031e88a492a75b3900924944658_1753948841898749.jpg

      When installing the online residual chlorine detector, businesses also need to adjust according to the water circulation direction of the pool. If it is a forward - flow circulation, the monitoring point can be set a little further forward; if it is a reverse - flow circulation, it should be set a little further back. In addition, the installation height of the sensor probe also matters. Generally, it should be 30 - 50cm away from the water surface. This is because there are often foams on the water surface, which can affect the monitoring results of the sensor. Keeping a certain height can avoid the interference of foams.

    9f91bd8d9659a6d6ad8e3402b3af8810_1754014597740003.jpg

      Scientific and reasonable arrangement of the installation points of the online residual chlorine detector can make it truly play its role. For swimming pool businesses, this not only helps to efficiently control water quality and safeguard the health of consumers but also enhances the business's reputation and competitiveness. If you encounter any problems in choosing the installation points, please feel free to consult the chlorine sensor Manufacturer, Maideshi Residual Chlorine Water Quality Sensor Factory, and let the detector become a reliable guardian of the swimming pool water quality safety.

      As a leading chlorine sensor Manufacturer, we provide high - quality Digital residual chlorine sensors and online residual chlorine detectors. Our products are designed to meet the needs of swimming pool businesses, ensuring accurate and reliable water quality monitoring. Choose our products and experience the difference in water quality management.




    Previous: Operating an Online Residual Chlorine Water Quality Monitor: Focusing Solely on Residual Chlorine Values Is a Mistake! These 6 Water Quality Parameters Are Crucial!
    Next: Is Your Residual Chlorine Always Exceeding the Standard? Enterprises, Stop Blindly Reducing Chemical Dosage! These 4 Hidden Reasons Are the Key to Repeated Exceedances!



    WeChat MADSUR