    Time:June 16, 2025

     

      In the daily production of enterprise users, are you often troubled by the fluctuations of the water body's pH value? The data of the online residual chlorine detector is always inaccurate, going up and down like a roller - coaster. Don't underestimate this data deviation. It affects not only a few numbers but also the entire production safety and cost control. For example, in a water treatment plant, if the residual chlorine monitoring data is inaccurate and the residual chlorine dosage is inappropriate, it may lead to sub - standard water quality, affecting the water safety of residents. In some chemical enterprises, inaccurate residual chlorine data may cause problems in the production process, resulting in the waste of raw materials and an increase in production costs. Data shows that due to the deviation of residual chlorine monitoring data, some enterprises' annual additional production costs can reach 10% - 20%.

      So, how exactly does the pH value interfere with residual chlorine monitoring? As a chlorine sensor Manufacturer, Maideshi will explain the underlying principle. Residual chlorine in water mainly exists in the forms of hypochlorous acid (HClO) and hypochlorite ions (ClO⁻), and the ratio between them changes with the change of the water body's pH value. When the pH value is low, the proportion of hypochlorous acid is high; when the pH value is high, the proportion of hypochlorite ions is high. The online residual chlorine detector mainly determines the residual chlorine concentration by detecting the content of hypochlorous acid. When the pH value fluctuates, the ratio of hypochlorous acid and hypochlorite ions changes, which leads to inaccurate signals detected by the detector and thus data deviation. Here is a real - life example. A paper mill didn't notice the influence of the water body's pH value on residual chlorine monitoring, and the residual chlorine monitoring data was always unstable. The quality of the produced paper was also inconsistent. Later, after analysis by professionals, it was found that the problem was caused by the pH value fluctuations.

      Don't worry. There are three solutions to this problem.

     Solution 1: Choose an Anti - interference Residual Chlorine Detector

      There are some residual chlorine detectors in the market that use specific technologies and have strong anti - interference capabilities. For example, [specific model] uses advanced sensor technology and algorithms, which can effectively reduce the impact of pH value fluctuations on the monitoring results. This kind of detector is like a "super guard" that can accurately detect the residual chlorine content in a complex water quality environment.

     Solution 2: Real - time pH Linked Compensation

      By installing a pH sensor, the pH value of the water body can be monitored in real - time, and the data is transmitted to the residual chlorine detector. The residual chlorine detector can intelligently calibrate the monitoring data according to the change of the pH value. It's like equipping the detector with a "smart brain" that can automatically adjust according to the actual situation to ensure the accuracy of the data.

     Solution 3: Scenario - based Monitoring Strategy

      The water body characteristics vary in different industries, and the applicable monitoring methods are also different. In the swimming pool industry, since the pH value of the water body is relatively stable, a more conventional monitoring method can be adopted. In a sewage treatment plant, the water body composition is complex and the pH value fluctuates greatly, so a more accurate monitoring method is needed. For example, multi - point monitoring can be adopted, and monitoring points can be set at different treatment stages to comprehensively understand the changes of residual chlorine and pH value.

      As a chlorine sensor Manufacturer, Maideshi has conducted a technical comparison to let you see the effects more intuitively. In the same water body environment, a common detector and a professional anti - interference detector were used for detection. When the pH value fluctuated, the data error of the common detector could reach 15% - 20%, while the error rate of the professional anti - interference detector could be controlled within 5%. From the difference in the actual measurement data, it is obvious that the professional anti - interference detector has significant advantages.

      If you also want to solve the problem of the water body's pH value interfering with residual chlorine monitoring, we have prepared a guide for you to avoid pitfalls when purchasing. Click to receive the exclusive enterprise solution and let the online residual chlorine detector or the digital residual chlorine sensor safeguard your production safety and cost control!

      In conclusion, ensuring the accuracy of the online residual chlorine detector in the face of pH value interference is crucial for enterprises. With the right solutions provided by our chlorine sensor Manufacturer, you can effectively deal with this problem. Whether it's a Digital residual chlorine sensor or an online residual chlorine detector, choosing the appropriate equipment and methods can bring better results to your production.