Home > Digital residual chlorine sensor
Products
  • Water Quality Sensor
  • Water Quality Testing
  • Online water quality electrode
  • Buoy Shore Station Series
  • Digital residual chlorine sensor

    Detection part using special permeable membrane technology, with resistant chemicals (mainly surfactant owner) interference, reduce PH dependence, sensor is not limited by water quality conditions, can be applied with tap water, swimming pool, sewage treatment, medical wastewater, industrial wastewater environment, sensor reaction speed, stable performance, low cost and less maintenance, to provide users with reliable and accurate data.

    Product overview

    Membrane residual nitrogen, total nitrogen and chlorine dihydrogenation electrode are composite digital electrode using membrane amperometric method. Detection part using special permeable membrane technology, with resistant chemicals (mainly surfactant owner) interference, reduce PH dependence, sensor is not limited by water quality conditions, can be applied with tap water, swimming pool, sewage treatment, medical wastewater, industrial wastewater environment, sensor reaction speed, stable performance, low cost and less maintenance, to provide users with reliable and accurate data.

    Typical applications, and the main features

    Conventional drinking water, tap water, swimming pool water and aquatic products are basically not affected by PH.

    Breeding, seawater. Digital signal data internal processing, without electromagnetic interference.

    Medical wastewater and medical sewage. Stable work, fast response speed.

    Dosing equipment, circulating water and cooling water. No zero-point calibration is required.

    Low cost, less maintenance workload.

    measuring range0~20ppm
    Ph scopePH:4~9
    Range of conductivity10 μ S / cm ~ 50 mS / cm (seawater)
    velocity of flowIn the circulation pool: 250 ~ 500 ml/min
    Slope driftAbout-1% per month
    response timeT90: about 2 minutes (reaching 90% of the measured value
    Zero point calibrationnon-essential
    Slope calibrationOn the measuring device, the analytical determination was performed by the DPD-1 method
    temperature compensationIntegrated with automatic temperature compensation
    material qualityPVC-U, stainless steel, and microporous hydrophilic film
    working temperatureMeasure water mixing: 0-45℃ (no condensation in water); environment chamber mixing: 0-55℃
    output signalDigital signal [MODBUSRS485 with isolation)
    sizeDiameter of 25mm * and 205mm in length





    WeChat MADSUR
    All rights reserved © 2025 Copyright MADSUR